4-8
Phaser 5500 Printer Service Manual
Verifying AC Power
AC Power Troubleshooting Reference
Applicable Parts
References
■
Power Cord
■
AC Accessory Panel
■
Wall Outlet
■
Print Engine Electrical Specifications (page 1-13)
■
AC Accessory Panel Plug/Jack Locator (page 10-15)
■
PL8.1 Print Engine Electrical (page 9-40)
AC Power Troubleshooting Procedure
Step
Actions and Questions
Yes
No
1
For 115 V:
1. Disconnect the AC power cord from the wall
outlet.
2. Measure the AC voltage between AC Line and
Neutral, between AC Line and Ground, and
between AC Neutral and Ground.
3. The voltage between Line and Neutral and
between Line and Ground should range from 99
to 135 VAC and the voltage between Neutral and
Ground should be less than 3 VAC.
Is the AC voltage within specification?
Go to Step 2.
Inform
customer of
insufficient
voltage or
improper
wiring.
For 220V:
1. Disconnect the AC power cord from the wall
outlet.
2. Measure the AC voltage between Line and
Neutral, between AC Line and Earth/Ground,
and between Neutral and Earth/Ground.
3. The voltage between Line and Neutral and
between Line and Earth/Ground should range
from 198 to 254 VAC and the voltage between
Neutral and Ground should be less than 3 VAC.
Is the AC line voltage within specification?
Go to Step 2.
Inform
customer of
insufficient
voltage or
improper
wiring.
AC Neutral
AC Line
s4400-285
s4400-286
Earth/GND
Earth/GND
Line
Line
Neutral
Neutral
Summary of Contents for Phaser 5500
Page 1: ......
Page 2: ......
Page 330: ...3 252 Phaser 5500 Printer Service Manual ...
Page 394: ...5 48 Phaser 5500 Printer Service Manual ...
Page 408: ...6 14 Phaser 5500 Printer Service Manual ...
Page 519: ...Parts Lists 9 15 This page intentionally left blank ...
Page 550: ...9 46 Phaser 5500 Printer Service Manual ...
Page 584: ...10 34 Phaser 5500 Printer Service Manual ...
Page 623: ...071 0873 00 A ...