Default Setting
Feature
Disabled
UDLD aggressive mode
Related Topics
Enabling UDLD Globally , on page 399
Enabling UDLD on an Interface , on page 400
How to Configure UDLD
Enabling UDLD Globally
Follow these steps to enable UDLD in the aggressive or normal mode and to set the configurable message
timer on all fiber-optic ports on the switch.
SUMMARY STEPS
1.
configure terminal
2.
udld
{
aggressive
|
enable
|
message time message-timer-interval
}
3.
end
DETAILED STEPS
Purpose
Command or Action
Enters global configuration mode.
configure terminal
Example:
Switch#
configure terminal
Step 1
Specifies the UDLD mode of operation:
udld
{
aggressive
|
enable
|
message
time message-timer-interval
}
Step 2
•
aggressive
—
Enables UDLD in aggressive mode on all fiber-optic ports.
Example:
Switch(config)#
udld enable
•
enable
—
Enables UDLD in normal mode on all fiber-optic ports on the
switch. UDLD is disabled by default.
An individual interface configuration overrides the setting of the
udld
enable
global configuration command.
message time 10
•
message time message-timer-interval
—
Configures the period of time
between UDLD probe messages on ports that are in the advertisement
phase and are detected to be bidirectional. The range is from 1 to 90
seconds; the default value is 15.
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
399
How to Configure UDLD
Summary of Contents for Catalyst 2960 Series
Page 96: ......
Page 196: ......
Page 250: ......
Page 292: ......
Page 488: ......
Page 589: ...P A R T VI Cisco Flexible NetFlow Configuring NetFlow Lite page 509 ...
Page 590: ......
Page 619: ...P A R T VII QoS Configuring QoS page 539 Configuring Auto QoS page 645 ...
Page 620: ......
Page 750: ......
Page 1604: ......
Page 1740: ......
Page 2105: ...P A R T XII Configuring Cisco IOS IP SLAs Configuring Cisco IP SLAs page 2025 ...
Page 2106: ......
Page 2118: ......
Page 2164: ......