Purpose
Command or Action
Configures a VTP administrative domain.
vtp domain domain-name
Step 3
Example:
Switch(config)#
vtp domain workdomain
The domain name can be 1 to 32 characters.
Configures Switch A as the VTP server.
vtp mode server
Example:
Switch(config)#
vtp mode server
Step 4
Returns to privileged EXEC mode.
end
Example:
Switch(config)#
end
Step 5
Verifies the VTP configuration on both Switch A and
Switch B.
show vtp status
Example:
Switch#
show vtp status
Step 6
In the display, check the
VTP Operating Mode
and the
VTP Domain Name
fields.
Verifies that the VLANs exist in the database on Switch
A.
show vlan
Example:
Switch#
show vlan
Step 7
Enters global configuration mode.
configure terminal
Example:
Switch#
configure terminal
Step 8
Defines the interface to be configured as a trunk, and
enters interface configuration mode.
interface interface-id
Example:
Switch(config)#
interface gigabitethernet1/0/1
Step 9
Configures the port as a trunk port.
switchport mode trunk
Example:
Switch(config-if)#
switchport mode trunk
Step 10
Consolidated Platform Configuration Guide, Cisco IOS Release 15.2(4)E (Catalyst 2960-X Switches)
2143
How to Configure VLAN Trunks
Summary of Contents for Catalyst 2960 Series
Page 96: ......
Page 196: ......
Page 250: ......
Page 292: ......
Page 488: ......
Page 589: ...P A R T VI Cisco Flexible NetFlow Configuring NetFlow Lite page 509 ...
Page 590: ......
Page 619: ...P A R T VII QoS Configuring QoS page 539 Configuring Auto QoS page 645 ...
Page 620: ......
Page 750: ......
Page 1604: ......
Page 1740: ......
Page 2105: ...P A R T XII Configuring Cisco IOS IP SLAs Configuring Cisco IP SLAs page 2025 ...
Page 2106: ......
Page 2118: ......
Page 2164: ......