26
Technical data
Type 8098 FLOWave L
Table 2:
Liquid pressure, depending on the pipe diameter, the type of process connections and the process
connection standard
Size of the process
connection
Type of process
connection
Standards the process connections
conform to
PN
DN08, DN15, DN25
clamp
•
DIN 11864-3 series B
•
DIN 32676 series A
•
DIN 32676 series B
PN25
flange
DIN 11864-2 series B
PN25
DN15, DN25
clamp
DIN 11864-3 series A
PN25
flange
DIN 11864-2 series A
PN25
DN25
clamp
SMS 3017 / ISO 2852 for pipes
according to SMS 3008
PN25
3/8", 1/2", 3/4", 1", 1 1/2"
clamp
ASME BPE (DIN 32676 series C)
PN25
1/2", 3/4", 1", 1 1/2"
clamp
DIN 11864-3 series C
PN25
flange
DIN 11864-2 series C
PN25
DN40
clamp
•
DIN 11864-3 series B
•
DIN 32676 series B
PN16
•
DIN 11864-3 series A
•
DIN 32676 series A
•
SMS 3017 / ISO 2852 for pipes
according to SMS 3008
PN25
flange
DIN 11864-2 series B
PN16
DIN 11864-2 series A
PN25
DN50
clamp
•
DIN 11864-3 series A
•
DIN 11864-3 series B
•
DIN 32676 series A
•
DIN 32676 series B
•
SMS 3017 / ISO 2852 for pipes
according to SMS 3008
PN16
flange
•
DIN 11864-2 series A
•
DIN 11864-2 series B
PN16
2"
clamp
•
ASME BPE (DIN 32676 series C)
•
DIN 11864-3 series C
PN16
flange
DIN 11864-2 series C
PN16
English
Summary of Contents for Flowave 8098
Page 4: ...General contents 4 Type 8098 FLOWave L English...
Page 12: ...12 Type 8098 FLOWave L English...
Page 36: ...36 Technical data Type 8098 FLOWave L English...
Page 72: ...72 Type 8098 FLOWave L English...
Page 78: ...78 Commissioning Type 8098 FLOWave L English...
Page 96: ...96 Type 8098 FLOWave L English...
Page 144: ...144 Type 8098 FLOWave L English...
Page 248: ...248 Type 8098 FLOWave L English...
Page 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Page 304: ...304 Type 8098 FLOWave L English...
Page 316: ...316 Type 8098 FLOWave L English...
Page 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Page 352: ...352 Appendix Type 8098 FLOWave L English...
Page 353: ......
Page 354: ...www burkert com...