54
Electrical installation
Type 8098 FLOWave L
NOTICE
If the screwed plug of a 4-pin M12 female connector is removed, the device is not tight.
▶
If the 4-pin M12 female connector is not used, do not remove the screwed plug.
▶
Screw the plug to the 4-pin M12 female connector to a torque of 1.3 Nm (0.96 ft·lbf).
NOTICE
The device with M20x1.5 cable glands is not tight if a cable gland is not used
▶
Make sure the unused M20x1.5 cable glands are sealed with the supplied plugs.
▶
When the blind plug is inserted, screw the cable-gland nut in stainless steel to a torque of 3 Nm
(2.21 ft·lbf).
▶
When the blind plug is inserted, screw the cable-gland nut in nickel plated brass to a torque of 8 Nm
(5.90 ft·lbf).
▶
Use a high quality electrical power supply, filtered and regulated.
▶
Do not install the cables near high voltage or high frequency cables; if this cannot be avoided,
observe a minimum distance of 30 cm.
On a device with M20x1.5 cable glands, put only one cable in each cable gland.
To do the electrical installation of a device with two 4-pin M12 female connectors (Ethernet device
variant) that is connected to an Ethernet network, observe standard ISO / IEC 61918.
8.2
Additional documentation
• For more information on büS, read the cabling guide available in English and in Japanese (Cabling_guide_
for_büS/EDIP.pdf) at
• For more information on CANopen that is related to the device, refer to the Operating Instructions
"CANopen Network configuration" at
•
If the device is an ATEX / IECEx device variant, then refer to the ATEX / IECEx supplement for
Type 8098 FLOWave L available on the internet at
.
8.3
Connecting the device to a power supply
The device is wired in the factory to be easily energized through the 5-pin M12 male connector.
→
Connect the device with two 4-pin M12 female connectors (Ethernet device variant) to a 12...35 V DC
power supply through the 5-pin M12 male connector; Refer to chapter
A device with two 4-pin M12 female connectors (Ethernet device variant) must be energized through
the 5-pin M12 male connector.
→
Connect the device with M20x1.5 cable glands to a 12...35 V DC power supply:
•
either through the 5-pin M12 male connector, refer to chapter
•
or through the M20x1.5 cable glands and the terminal strip located in the transmitter housing. Refer to
chapter 8.13
for the wiring procedure.
English
Summary of Contents for Flowave 8098
Page 4: ...General contents 4 Type 8098 FLOWave L English...
Page 12: ...12 Type 8098 FLOWave L English...
Page 36: ...36 Technical data Type 8098 FLOWave L English...
Page 72: ...72 Type 8098 FLOWave L English...
Page 78: ...78 Commissioning Type 8098 FLOWave L English...
Page 96: ...96 Type 8098 FLOWave L English...
Page 144: ...144 Type 8098 FLOWave L English...
Page 248: ...248 Type 8098 FLOWave L English...
Page 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Page 304: ...304 Type 8098 FLOWave L English...
Page 316: ...316 Type 8098 FLOWave L English...
Page 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Page 352: ...352 Appendix Type 8098 FLOWave L English...
Page 353: ......
Page 354: ...www burkert com...