Installation in the pipe
Type 8098 FLOWave L
7.5
Installing the device into the pipe
CAUTION
Risk of injury due to a heavy device.
A heavy device can fall down during transport or during installation and cause injuries.
▶
Transport, install and dismantle a heavy device with the help of another person.
▶
Use appropriate tools.
7.5.1
Before installing the device into the pipe
•
Prepare the device as described in chapter 7.3
•
Follow the recommendations given in chapter 7.4
.
7.5.2
Installing a device with clamp connections
The device manufacturer does not supply any gaskets for the process connections.
→
If the installation must be EHEDG-compliant and the device is fitted with clamp connections according
to ASME BPE (DIN 32676 series C), DIN 32676 series A, DIN 32676 series B or SMS 3017 / ISO 2852 for
pipes according to SMS 3008, then use EHEDG-compliant gaskets from Combifit International B.V.
→
To make sure that you use EHEDG-compliant gaskets, refer to the "EHEDG Position Paper" available on
the EHEDG website.
→
The clamp connections according to DIN 11864-3 series A, B and C are hygienic connections. You can
use any gaskets that are adapted to the process.
→
Make sure that the gaskets on the clamp connections are in good condition.
→
Place gaskets adapted to the process (temperature, liquid type) in the grooves of the clamp connections.
→
Attach the clamp connections to the pipe with clamp collars. Make sure that tightening the clamp does
not create bulges at the gaskets. Gasket bulges can lead to wrong measurements.
7.5.3
Installing a device with flange connections
→
The flange connections according to DIN 11864-2 series A, B and C are hygienic connections. You can
use any gaskets that are adapted to the process.
→
Make sure that the gaskets on the flange connections are in good condition.
→
Place gaskets adapted to the process (temperature, liquid type) in the grooves of the flange connections.
→
Use bolts with dimensions as given in the relevant flange standard and adapted to the process.
→
Tighten the bolts to a torque as given in the relevant flange standard to fix the fitting to the pipe.
English
Summary of Contents for Flowave 8098
Page 4: ...General contents 4 Type 8098 FLOWave L English...
Page 12: ...12 Type 8098 FLOWave L English...
Page 36: ...36 Technical data Type 8098 FLOWave L English...
Page 72: ...72 Type 8098 FLOWave L English...
Page 78: ...78 Commissioning Type 8098 FLOWave L English...
Page 96: ...96 Type 8098 FLOWave L English...
Page 144: ...144 Type 8098 FLOWave L English...
Page 248: ...248 Type 8098 FLOWave L English...
Page 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Page 304: ...304 Type 8098 FLOWave L English...
Page 316: ...316 Type 8098 FLOWave L English...
Page 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Page 352: ...352 Appendix Type 8098 FLOWave L English...
Page 353: ......
Page 354: ...www burkert com...