331
Maintenance and troubleshooting
Type 8098 FLOWave L
24.9.23
Message "Totalizer 1 started" / "Totalizer 2 started" or "Mass
totalizer 1 started" / "Mass totalizer 2 started"
Message
Totalizer 1 started / Totalizer 2 started
or
Mass totalizer 1 started / Mass totalizer 2 started
Symbol displayed in the
information bar
-
Possible cause
The related totalizer
/ mass totalizer has been started by the user.
What to do?
-
24.10
Messages due to calibration or simulation
24.10.1
Message "Calibration result out of range"
Message
Calibration result out of range
Symbol displayed in the
information bar
(symbol changed)
Possible cause
The calibration has failed.
The calibration has failed because of 1 of the pos
-
sible causes:
• An event such as
Change of liquid
or
Sound cond. out of range
has
been generated during the calibration.
•
The calculated offset of the DF is lower than 0.5 or higher than 2.
•
The calculated offset of the acoustic transmission factor is lower than 0.5
or higher than 2.
What to do?
→
Make sure the liquid is the same during the calibration procedure.
→
Make sure the conditions are met to measure the flow rate correctly.
→
Do a new calibration.
24.10.2
Message "Zero calibration cancelled, the flow rate is higher
than 5 % of full scale"
Message
Zero calibration cancelled, the flow rate is higher than 5 % of full scale
Symbol displayed in the
information bar
Possible cause
The calibration has failed because the
flow rate is less than 5 % of the full
scale.
What to do?
→
Make sure the flow is stopped in the pipe.
→
Do a new calibration.
English
Summary of Contents for Flowave 8098
Page 4: ...General contents 4 Type 8098 FLOWave L English...
Page 12: ...12 Type 8098 FLOWave L English...
Page 36: ...36 Technical data Type 8098 FLOWave L English...
Page 72: ...72 Type 8098 FLOWave L English...
Page 78: ...78 Commissioning Type 8098 FLOWave L English...
Page 96: ...96 Type 8098 FLOWave L English...
Page 144: ...144 Type 8098 FLOWave L English...
Page 248: ...248 Type 8098 FLOWave L English...
Page 286: ...286 SAW sensor Maintenance Type 8098 FLOWave L English...
Page 304: ...304 Type 8098 FLOWave L English...
Page 316: ...316 Type 8098 FLOWave L English...
Page 350: ...350 Spare parts and accessories Type 8098 FLOWave L English...
Page 352: ...352 Appendix Type 8098 FLOWave L English...
Page 353: ......
Page 354: ...www burkert com...