68
Electrical installation
Type 8098 FLOWave L
8.15
Wiring output 2 (digital) and output 3 configured as a
digital output (device variant with cable glands)
NOTICE
Risk of short-circuit if the configuration of output 3 is wrong.
▶
Before wiring output 3 as a digital output, make sure output 3 is configured as a digital output in the
Parameter menu of the outputs. See chapter 18.2 Changing the type of output 3
A digital output can be wired either in NPN mode or in PNP mode.
1
1 2 3 4 5 6 7 8 9 1 1 2
1
0
+
-
+
-
12-35 V DC
+
-
12-35 V DC
+
-
Load connected
to output 3
Load connected
to output 2
Power supply for
output 3
Power supply for
output 2
Orange LED is lit if the
related digital output is
switched to ON
Fig. 34:
Wiring the digital outputs
English