Fault tracing
320
0033
BRAKE START TORQUE
(0x7185)
Programmable fault:
Mechanical brake fault. Fault is
activated if required motor
starting torque,
, is not achieved.
Check brake open torque setting, parameter
.
Check drive torque and current limits. See
parameter group
on page
.
0034
BRAKE NOT CLOSED
(0x7186)
Programmable fault:
Mechanical brake control fault.
Fault is activated if brake
acknowledgement is not as
expected during brake closing.
Check mechanical brake connection.
Check mechanical brake settings, parameters
.
To determine whether problem is with
acknowledgement signal or brake: Check if
brake is closed or open.
0035
BRAKE NOT OPEN
(0x7187)
Programmable fault:
Mechanical brake control fault.
Fault is activated if brake
acknowledgement is not as
expected during brake opening.
Check mechanical brake connection.
Check mechanical brake settings, parameters
.
To determine whether problem is with
acknowledgement signal or brake: Check if
brake is closed or open.
0036
LOCAL CTRL LOSS
(0x5300)
Programmable fault:
Control panel or PC tool
selected as active control
location for drive has ceased
communicating.
Check PC tool or control panel connection.
Check control panel connector.
Replace control panel in mounting platform.
0037
NVMEMCORRUPTED
(0x6320)
Drive internal fault
Note:
This fault cannot be
reset.
Check the fault logger for a fault code
extension. See appropriate actions for each
extension below.
Fault code extension: 2051
Total number of parameters
(including unused space
between parameters) exceeds
firmware maximum.
Move parameters from the firmware groups to
the application groups.
Reduce the number of parameters.
Fault code extension:
Other
Drive internal fault.
Contact your local ABB representative.
0038
OPTION COMM LOSS
(0x7000)
Communication between drive
and option module (FEN-xx
and/or FIO-xx) is lost.
Check that option modules are properly
connected to Slot 1 and (or) Slot 2.
Check that option modules or Slot 1/2
connectors are not damaged. To determine
whether module or connector is damaged:
Test each module individually in Slot 1 and
Slot 2.
Speed feedback (
) has been selected
from an encoder which does not
supply a speed feedback. SSI
and EnDat type absolute
encoders do not supply speed
feedback when in the
'Continuous' mode (
,
).
In this case, either the estimated speed value
must be used, or another encoder mode must
be selected. Check parameters
and
/
Code
Fault
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...