Parameter data
299
68.03 SYNC GEAR DIV
UINT32
1…2
31
- 1
-
1 = 1
10 ms
32
1
WPD
68.04 SYNC GEAR ADD
REAL
-30…30
-
1 = 1000
500 µs
32
1
68.05 SYNC REF FTIME
REAL
0…1000
ms
1 = 1
10 ms
16
0
WPD
68.06 SYNCFILT DLY LIM
REAL
0…120
*
10 ms
32
0
68.07 SYNCHRON MODE
enum
0…1
-
1 = 1
2 ms
16
1
70
POS REF LIMIT
70.01 POS REF PROFILE
Val pointer
-
-
-
500 µs
32
P.04.13
70.02 POS REF SYNC
Val pointer
-
-
-
500 µs
32
P.04.16
70.03 POS REF ENA
Bit pointer
-
-
-
500 µs
32
C.True
70.04 POS SPEED LIM
REAL
0…32768
**
See
2 ms
32
32768
70.05 POS ACCEL LIM
REAL
0…32768
**
See
2 ms
32
32768
70.06 POS DECEL LIM
REAL
-32768…0
**
2 ms
32
-32768
70.07 SYNC ERR LIM
REAL
0…32768
*
See
500 µs
32
32768
70.08 SYNC VEL WINDOW
REAL
0…32768
**
See
2 ms
32
2
71
POSITION CTRL
71.01 POS ACT IN
Val pointer
-
-
-
500 µs
32
P.01.12
WP
71.02 POS CTRL REF IN
Val pointer
-
-
-
500 µs
32
P.04.17
71.03 POS CTRL GAIN
REAL
0…10000
1/s
1 = 100
500 µs
32
10
71.04 P CTRL FEED GAIN
REAL
0…10
-
1 = 100
500 µs
16
1
71.05 POS CTRL DELAY
UINT32
0…15
-
1 = 1
2 ms
16
0
71.06 POS ERR LIM
REAL
0…32768
*
500 µs
32
32768
71.07 GEAR RATIO MUL
INT32
-2
31
…2
31
-
1
-
1 = 1
10 ms
32
1
71.08 GEAR RATIO DIV
UINT32
1…2
31
- 1
-
1 = 1
10 ms
32
1
71.09 FOLLOW ERR WIN
REAL
0…32768
*
500 µs
32
32768
90
ENC MODULE SEL
90.01 ENCODER 1 SEL
enum
0…6
-
1 = 1
16
0
90.02 ENCODER 2 SEL
enum
0…6
-
1 = 1
16
0
90.03 EMUL MODE SEL
enum
0…9
-
1 = 1
16
0
90.04 TTL ECHO SEL
enum
0…4
-
1 = 1
16
0
90.05 ENC CABLE FAULT
UINT32
0…2
-
1 = 1
16
1
90.06 INVERT ENC SIG
enum
0…3
-
1 = 1
-
16
0
90.10 ENC PAR REFRESH
UINT32
0…1
-
1 = 1
16
0
WPD
91
ABSOL ENC CONF
91.01 SINE COSINE NR
UINT32
0…65535
-
1 = 1
16
0
91.02 ABS ENC INTERF
enum
0…5
-
1 = 1
16
0
91.03 REV COUNT BITS
UINT32
0…32
-
1 = 1
16
0
91.04 POS DATA BITS
UINT32
0…32
-
1 = 1
16
0
91.05 REFMARK ENA
UINT32
0…1
-
1 = 1
16
0
91.06 ABS POS TRACKING
UINT32
0…1
-
1 = 1
16
0
91.10 HIPERFACE PARITY
UINT32
0…1
-
1 = 1
16
0
91.11 HIPERF BAUDRATE
UINT32
0…3
-
1 = 1
16
1
91.12 HIPERF NODE ADDR
UINT32
0…255
-
1 = 1
16
64
91.20 SSI CLOCK CYCLES
UINT32
2…127
-
1 = 1
16
2
Index
Parameter
Type
Range
Unit
FbEq
Update
time
Data
length
Def
PT
Save
PF
Page
no.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...