Fault tracing
306
2007
RUN ENABLE
(0xFF54)
No Run enable signal is
received.
Check setting of parameter
. Switch signal on (eg, in the fieldbus
Control Word) or check wiring of selected
source.
2008
ID-RUN
(0xFF84)
Motor identification run is on.
This alarm belongs to normal start-up
procedure. Wait until drive indicates that
motor identification is completed.
Motor identification is required.
This alarm belongs to normal start-up
procedure.
Select how motor identification should be
performed, parameter
Start identification routines by pressing Start
key.
2009
EMERGENCY STOP
(0xF081)
Drive has received emergency
stop command (OFF1/OFF3).
Check that it is safe to continue operation.
Return emergency stop push button to normal
position (or adjust the fieldbus Control Word
accordingly).
Restart drive.
2010
POSITION SCALING
(0x8584)
Overflow or underflow in
position calculation (caused by
used position scaling).
Check position scaling parameter settings:
…
Check speed scaling parameter settings:
2011
BR OVERHEAT
(0x7112)
Braking resistor temperature
has exceeded alarm limit
defined by parameter
Stop drive. Let resistor cool down.
Check resistor overload protection function
settings, parameters
Check alarm limit setting, parameter
.
Check that braking cycle meets allowed
limits.
2012
BC OVERHEAT
(0x7181)
Braking chopper IGBT
temperature has exceeded
internal alarm limit.
Let chopper cool down.
Check for excessive ambient temperature.
Check for cooling fan failure.
Check for obstructions in the air flow.
Check the dimensioning and cooling of the
cabinet.
Check resistor overload protection function
settings, parameters
Check that braking cycle meets allowed
limits.
Check that drive supply AC voltage is not
excessive.
Code
Alarm
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...