![ABB ACSM1 Series Manual Download Page 325](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326325.webp)
Fault tracing
325
0067
FPGA ERROR1
(0x5401)
Drive internal fault
Contact your local ABB representative.
0068
FPGA ERROR2
(0x5402)
Drive internal fault
Contact your local ABB representative.
0069
ADC ERROR
(0x5403)
Drive internal fault
Contact your local ABB representative.
0073
ENC 1 PULSE
FREQUENCY
(0x738B)
Encoder 1 is receiving too high
data flow (pulse frequency).
Check encoder settings.
Change parameters
to use only one channel pulses/
edges.
0074
ENC 2 PULSE
FREQUENCY
(0x738C)
Encoder 2 is receiving too high
data flow (pulse frequency).
Check encoder settings.
Change parameters
to use only one channel pulses/
edges.
0075
MOT OVERFREQUENCY
(0x7390)
Inverter output (motor)
frequency has exceeded the
frequency limit 599 Hz.
Reduce the motor rotation speed.
0201
T2 OVERLOAD
(0x0201)
Firmware time level 2 overload
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0202
T3 OVERLOAD
(0x6100)
Firmware time level 3 overload
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0203
T4 OVERLOAD
(0x6100)
Firmware time level 4 overload
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0204
T5 OVERLOAD
(0x6100)
Firmware time level 5 overload
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0205
A1 OVERLOAD
(0x6100)
Application time level 1 fault
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0206
A2 OVERLOAD
(0x6100)
Application time level 2 fault
Note:
This fault cannot be
reset.
Contact your local ABB representative.
0207
A1 INIT FAULT
(0x6100)
Application task creation fault
Note:
This fault cannot be
reset.
Contact your local ABB representative.
Code
Fault
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...