Standard function blocks
340
Bitwise
BGET
(10034)
Illustration
Execution time
0.88 µs
Operation
The output (O) is the value of the selected bit (BITNR) of the input (I).
BITNR: Bit number (0 = bit number 0, 31 = bit number 31)
If bit number is not in the range of 0…31 (for DINT) or 0…15 (for INT), the output is 0.
Inputs
The input data type is selected by the user.
Number of the bit (BITNR): DINT
Input (I): DINT, INT
Outputs
Output (O): Boolean
BITAND
(10035)
Illustration
Execution time
0.32 µs
Operation
The output (O) bit value is 1 if the corresponding bit values of the inputs (I1 and I2)
are 1. Otherwise the output bit value is 0.
Example:
Inputs
Input (I1, I2): DINT
Outputs
Output (O): DINT
BGET
(DINT)
64
TLA1 1 msec
(1)
BITNR
I
O
O(64)
BITAND
65
TLA1 1 msec
(1)
I1
I2
O
O(65)
I1
1 1 1 0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 1
I2
0 0 0 0 0 1 1 1 0 0 1 0 1 1 1 0 1 0 0 1 1 0 0 1 1 0 1 0 1 1 1 1
O
0 0 0 0 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 1 0 0 0 1 0 0 1 0 0 1 0 1
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...