Parameter data
284
Actual signals (Parameter groups 1…9)
Index
Name
Type
Range
Unit
FbEq
Update
time
Data
length
PT
Save
PF
Page
no.
01
ACTUAL VALUES
1.01
SPEED ACT
REAL
-30000…30000
rpm
1 = 100
250 µs
32
WP
1.02
SPEED ACT PERC
REAL
-1000…1000
%
1 = 100
2 ms
32
WP
1.03
FREQUENCY
REAL
-30000…30000
Hz
1 = 100
2 ms
32
WP
1.04
CURRENT
REAL
0…30000
A
1 = 100
10 ms
32
WP
1.05
CURRENT PERC
REAL
0…1000
%
1 = 10
2 ms
16
WP
1.06
TORQUE
REAL
-1600…1600
%
1 = 10
2 ms
16
WP
1.07
DC-VOLTAGE
REAL
-
V
1 = 100
2 ms
32
WP
1.08
ENCODER 1 SPEED
REAL
-
rpm
1 = 100
250 µs
32
WP
1.09
ENCODER 1 POS
REAL24
-
rev
1=100000000 250 µs
32
WP
1.10
ENCODER 2 SPEED
REAL
-
rpm
1 = 100
250 µs
32
WP
1.11
ENCODER 2 POS
REAL24
-
rev
1=100000000 250 µs
32
WP
1.12
POS ACT
REAL
-32768…32767
*
See
250 µs
32
WP
1.13
POS 2ND ENC
REAL
-32768…32767
revs
1 = 1
250 µs
32
WP
1.14
SPEED ESTIMATED
REAL
-30000…30000
rpm
1 = 100
2 ms
32
WP
1.15
TEMP INVERTER
REAL24
-40…160
°C
1 = 10
2 ms
16
WP
1.16
TEMP BC
REAL24
-40…160
°C
1 = 10
2 ms
16
WP
1.17
MOTOR TEMP
REAL
-10…250
°C
1 = 10
10 ms
16
WP
1.18
MOTOR TEMP EST
INT32
-60…1000
°C
1 = 1
10 ms
16
WP
x
1.19
USED SUPPLY VOLT
REAL
0…1000
V
1 = 10
10 ms
16
WP
1.20
BRAKE RES LOAD
REAL24
0…1000
%
1 = 1
50 ms
16
WP
1.21
CPU USAGE
UINT32
0…100
%
1 = 1
100 ms
16
WP
1.22
INVERTER POWER
REAL
-2
31
…2
31
- 1
kW
1 = 100
10 ms
32
WP
1.26
ON TIME COUNTER
INT32
0…35791394.1
h
1 = 100
10 ms
32
WP0
x
1.27
RUN TIME COUNTER
INT32
0…35791394.1
h
1 = 100
10 ms
32
WP0
x
1.28
FAN ON-TIME
INT32
0…35791394.1
h
1 = 100
10 ms
32
WP0
x
1.31
MECH TIME CONST
REAL
0…32767
s
1 = 1000
10 ms
32
WP
x
1.38
TEMP INT BOARD
REAL24
-40…160
°C
1 = 10
2 ms
16
WP
1.39
OUTPUT VOLTAGE
REAL
0…1000
V
1 = 1
10 ms
16
WP
1.42
FAN START COUNT
INT32
0...2147483647
-
1 = 1
10 ms
32
WP
x
02
I/O VALUES
2.01
DI STATUS
Pb
0…0x3F
-
1 = 1
2 ms
16
WP
2.02
RO STATUS
Pb
-
-
1 = 1
2 ms
16
WP
2.03
DIO STATUS
Pb
-
-
1 = 1
2 ms
16
WP
2.04
AI1
REAL
-
V or mA
1 = 1000
2 ms
16
WP
2.05
AI1 SCALED
REAL
-
-
1 = 1000
250 µs
32
WP
2.06
AI2
REAL
-
V or mA
1 = 1000
2 ms
16
WP
2.07
AI2 SCALED
REAL
-
-
1 = 1000
250 µs
32
WP
2.08
AO1
REAL
-
mA
1 = 1000
2 ms
16
WP
2.09
AO2
REAL
-
V
1 = 1000
2 ms
16
WP
2.10
DIO2 FREQ IN
REAL
-32768…32768
-
1 = 1000
2 ms
32
WP
2.11
DIO3 FREQ OUT
REAL
-32768…32768
Hz
1 = 1000
2 ms
32
WP
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...