![ABB ACSM1 Series Manual Download Page 80](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326080.webp)
Drive control and features
80
• Rising edge of encoder DI1 (proximity switch signal) is detected at the first mark
of the belt. Position 0 mm is stored to signal
.
• Next rising edge of encoder DI1 (proximity switch signal) is detected at the
second mark of the belt. Position 30 mm is stored to signal
.
• The reference distance between the marks is 40 mm and the measured distance
between the marks is 30 mm, thus the error is 10 mm:
(
)] = (40 - 0) - (30 - 0) = 10 mm
Note:
Only after the active correction is finished is the next position latching enabled.
t
t
t
Encoder DI1
POSITION DERIVATION
MEASURED POSITION DIFFERENCE