Standard function blocks
362
CTD_DINT
(10046)
Illustration
Execution time
0.92 µs
Operation
The counter output (CV) value is decreased by 1 if the counter input (CD) value
changes from 0 -> 1 and the load input (LD) value is 0. If the load input (LD) value is 1,
the preset input (PV) value is stored as the counter output (CV) value. If the counter
output has reached its minimum value -2147483648, the counter output remains
unchanged.
The status output (Q) is 1 if the counter output (CV) value < 0.
Example:
Inputs
Load input (LD): Boolean
Counter input (CD): Boolean
Preset input (PV): DINT
Outputs
Counter output (CV): DINT
Status output (Q): Boolean
CTU
(10049)
Illustration
Execution time
0.92 µs
CTD_DINT
94
TLA1 1 msec
(1)
LD
>CD
PV
CV
CV(94)
Q
Q(94)
LD
CD
PV
Q
CV
prev
CV
0
1 -> 0
10
0
5
5
0
0 -> 1
10
0
5
5 - 1 = 4
1
1 -> 0
-2
1
4
-2
1
0 -> 1
1
0
-2
1
0
0 -> 1
5
1
1
1 -1 = 0
1
1 -> 0
-2147483648
1
0
-2147483648
0
0 -> 1
10
1
-2147483648 -2147483648
CV
prev
is the previous cycle counter output value.
CTU
95
TLA1 1 msec
(1)
>CU
R
PV
CV
CV(95)
Q
Q(95)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...