Appendix C – Homing methods
484
Homing method 30
1
If the state of the home switch is 0 (par.
): Start in the negative (left)
direction by the rising edge of the signal selected by par.
with homing
.
2
Stop by the falling edge of the home switch signal selected by par.
.
1
2
Homing method 30
Homing start (par.
1
If the state of the home switch is 0 (par.
): Start in the negative (left)
direction by the rising edge of the signal selected by par.
with homing
.
2
Change direction by the rising edge of the negative limit switch signal selected by par.
.
3
Change direction by the rising edge of the home switch signal selected by par.
4
Stop by the falling edge of the home switch signal selected by par.
.
2
1
3
4
Homing method 30
)
Home switch (par.
)
Negative limit switch (par.
)
Summary of Contents for ACSM1 Series