![ABB ACSM1 Series Manual Download Page 274](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326274.webp)
Parameters and firmware blocks
274
Group
98 MOTOR CALC VALUES
Calculated motor values.
98
98.01
TORQ NOM SCALE
FW block: None
Nominal torque in N•m which corresponds to 100%.
Note:
This parameter is copied from parameter
if given. Otherwise the
value is calculated.
0…2147483 Nm
Nominal torque.
98.02
POLEPAIRS
FW block: None
Calculated number of motor pole pairs.
Note:
This parameter cannot be set by the user.
0…1000
Calculated number of motor pole pairs.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...