Fault tracing
312
2041
MOTOR NOM VALUE
(0x6383)
The motor configuration
parameters are set incorrectly.
Check the settings of the motor configuration
parameters in group
.
The drive is not dimensioned
correctly.
Check that the drive is sized correctly for the
motor.
2042
D2D CONFIG
(0x7583)
The settings of drive-to-drive
link configuration parameters
(group
) are incompatible.
Check the settings of the parameters in group
.
2043
STALL
(0x7121)
Programmable fault:
Motor is operating in stall region
because of, eg, excessive load
or insufficient motor power.
Check motor load and drive ratings.
Check fault function parameters.
2047
SPEED FEEDBACK
(0x8480)
No speed feedback is received.
Check the settings of the parameters in group
.
Check encoder installation. See the
description of fault
(ENCODER1) for
more information.
Check encoder cabling. See the descriptions
of alarms
(ENCODER 1 CABLE) and
(ENCODER 2 CABLE) for more
information.
2048
OPTION COMM LOSS
(0x7000)
Communication between drive
and option module (FEN-xx
and/or FIO-xx) is lost.
Check that option modules are properly
connected to Slot 1 and (or) Slot 2.
Check that option modules or Slot 1/2
connectors are not damaged. To determine
whether module or connector is damaged:
Test each module individually in Slot 1 and
Slot 2.
2072
DC NOT CHARGED
(0x3250)
The voltage of the intermediate
DC circuit has not yet risen to
operating level.
Wait for the DC voltage to rise.
2073
SPEED CTRL TUNE FAIL
(0x8481)
Speed controller autotune
routine did not finish
successfully.
See parameter
2075
LOW VOLT MODE
CONFIG
(0xC015)
Low voltage mode has been
activated but the parameter
settings are outside allowable
limits.
Check the Low voltage mode parameters in
group
on page
.
2079
ENC 1 PULSE
FREQUENCY
(0x738B)
Encoder 1 is receiving too high
data flow (pulse frequency).
Check encoder settings.
Change parameters
to use only one channel pulses/
edges.
Code
Alarm
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...