Parameters and firmware blocks
275
Group
99 START-UP DATA
Start-up settings such as language, motor data and motor control mode.
The nominal motor values must be set before the drive is started; for detailed
instructions, see chapter
on page
.
With DTC motor control mode, parameters
must be set; better control
accuracy is achieved by also setting parameters
.
With scalar control, parameters
must be set.
99
99.01
LANGUAGE
FW block: None
Selects the language.
Note:
Not all languages listed below are necessarily supported.
(0809h)
ENGLISH
English.
(0407h)
DEUTSCH
German.
(0410h)
ITALIANO
Italian.
(040Ah)
ESPAÑOL
Spanish.
(041Dh)
SVENSKA
Swedish.
(041Fh)
TÜRKÇE
Turkish.
99.04
MOTOR TYPE
FW block: None
Selects the motor type.
Note:
This parameter cannot be changed while the drive is running.
(0)
AM
Asynchronous motor. Three phase AC voltage supplied induction
motor with squirrel cage rotor.
(1)
PMSM
Permanent magnet motor. Three phase AC voltage supplied
synchronous motor with permanent magnet rotor and sinusoidal
BackEMF voltage.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...