Start-up
16
Safety
The start-up may only be carried out by a qualified electrician.
The safety instructions must be followed during the start-up procedure. See the safety
instructions on the first pages of the appropriate hardware manual.
Check the installation. See the installation checklist in the appropriate hardware manual.
Check that the starting of the motor does not cause any danger.
De-couple the driven machine
if
- there is a risk of damage in case of an incorrect direction of rotation, or
- a normal motor ID run (
) is required during the drive start-
up, when the load torque is higher than 20% or the machinery is not able to withstand the
nominal torque transient during the motor ID run.
PC tool
Install the DriveStudio PC tool onto the PC. Install also DriveSPC if block programming is
needed. For instructions, see
DriveStudio User Manual
[3AFE68749026 (English)] and
DriveSPC User Manual
[3AFE68836590 (English)].
Connect the drive to the PC:
Connect the other end of the communication cable (OPCA-02, code: 68239745) to the panel
link of the drive. Connect the other end of the communication cable via USB adapter or
directly to the PC serial port.
Power up
Switch the power on.
7-segment display:
Note:
The drive will indicate an alarm (2021 NO MOTOR DATA) until the motor data is entered later
in this procedure. This is completely normal.
Start the DriveStudio program by clicking the DriveStudio icon on the
PC desktop.
Check whether an application program exists using the DriveStudio
tool. If it does, the rows SOLUTION PROGRAM (SP) and SP EMPTY
TEMPLATE are displayed in drive properties (View - Properties,
Software category).
If an application program already exists, NOTE that some of the drive
functions may have been disabled. ENSURE that the application
program is suitable for your drive application.
Switch to local control to ensure that external control is disabled by
clicking the Take/Release button of the DriveStudio tool control panel.
->
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...