Fault tracing
317
0017
ID-RUN FAULT
(0xFF84)
Motor ID run is not completed
successfully.
Check the fault logger for a fault code
extension. See appropriate actions for each
extension below.
Extension: 1
The motor ID run cannot be
completed because the
maximum current setting and/or
the internal current limit of the
drive is too low.
and
. Make sure that
>
Check that the drive is dimensioned correctly
according to the motor.
Extension: 2
The motor ID run cannot be
completed because the
maximum speed setting and/or
calculated field weakening point
is too low.
,
,
. Make
sure that
•
) > (0.50 × synchronous
speed),
•
< 0, and
• supply voltage > (0.66 ×
Extension: 3
The motor ID run cannot be
completed because the
maximum torque setting is too
low.
and
. Make sure that
> 100%.
Extension: 5…8
Internal error.
Contact your local ABB representative.
Extension: 9
Asynchronous motors only:
Acceleration did not finish within
reasonable time.
Contact your local ABB representative.
Extension: 10
Asynchronous motors only:
Deceleration did not finish
within reasonable time.
Contact your local ABB representative.
Extension: 11
Asynchronous motors only:
Speed dropped to zero during
motor ID run.
Contact your local ABB representative.
Extension: 12
Permanent magnet motors only:
First acceleration did not finish
within reasonable time.
Contact your local ABB representative.
Extension: 13
Permanent magnet motors only:
Second acceleration did not
finish within reasonable time.
Contact your local ABB representative.
Extension: 14…16
Internal error.
Contact your local ABB representative.
0018
CURR U2 MEAS
(0x3184)
Measured offset error of U2
output phase current
measurement is too great.
(Offset value is updated during
current calibration.)
Contact your local ABB representative.
Code
Fault
(fieldbus code)
Cause
What to do
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...