Parameters and firmware blocks
98
2.13
FBA MAIN SW
(page
)
Status Word for fieldbus communication. See
on page
Bit
Name
Value
Information
0
READY
1
Drive is ready to receive start command.
0
Drive is not ready.
1
ENABLED
1
External run enable signal is received.
0
No external run enable signal is received.
2
RUNNING
1
Drive is modulating.
0
Drive is not modulating.
3
REF RUNNING 1
Normal operation is enabled. Drive is running and following given
reference.
0
Normal operation is disabled. Drive is not following given reference
(for example, modulating during magnetization).
4
EM OFF
(OFF2)
1
Emergency OFF2 is active.
0
Emergency OFF2 is inactive.
5
EM STOP
(OFF3)
1
Emergency stop OFF3 (ramp stop) is active.
0
Emergency OFF3 is inactive.
6
ACK
STARTINH
1
Start inhibit is active.
0
Start inhibit is inactive.
7
ALARM
1
An alarm is active. See chapter
.
0
No alarm is active.
8
AT SETPOINT
1
Drive is at setpoint. Actual value equals reference value (ie, the
difference between the actual speed and the speed reference is within
the speed window defined by
).
0
Drive has not reached setpoint.
9
LIMIT
1
Operation is limited by any torque or current limit.
0
Operation is within torque/current limits.
10 ABOVE LIMIT
1
Actual speed exceeds the defined limit,
0
Actual speed is within the defined limits.
11 EXT2 ACT
1
External control location EXT2 is active.
0
External control location EXT1 is active.
12 LOCAL FB
1
Fieldbus local control is active.
0
Fieldbus local control is inactive.
13 ZERO SPEED
1
Drive speed is below limit set by par.
0
Drive has not reached zero speed limit.
14 REV ACT
1
Drive is running in reverse direction.
0
Drive is running in forward direction.
15 Not in use
16 FAULT
1
Fault is active. See chapter
.
0
No fault is active.
17 LOCAL PANEL 1
Local control is active, ie, drive is controlled from PC tool or control
panel.
0
Local control is inactive.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...