Standard function blocks
385
Outputs
Output (O): REAL
High limit output (O=HL): Boolean
Low limit output (O=LL): Boolean
MOTPOT
(10067)
Illustration
Execution time
2.92 µs
Operation
The motor potentiometer function controls the rate of change of the output from the
minimum to the maximum value and vice versa.
The function is enabled by setting the ENABLE input to 1. If the up input (UP) is 1, the
output reference (OUTPUT) is increased to the maximum value (MAXVAL) with the
defined ramp time (RAMPTIME). If the down input (DOWN) is 1, the output value is
decreased to the minimum value (MINVAL) with the defined ramp time. If the up and
down inputs are activated/deactivated simultaneously, the output value is not increased/
decreased.
If the RESET input is 1, the output will be reset to the value defined by the reset value
input (RESETVAL) or to the value defined by the minimum input (MINVAL), whichever is
higher.
If the ENABLE input is 0, the output is zero.
Digital inputs are normally used as up and down inputs.
Inputs
Function enable input (ENABLE): Boolean
Up input (UP): Boolean
Down input (DOWN): Boolean
Ramp time input (RAMPTIME): REAL (seconds) (i.e. the time required for the output to
change from the minimum to the maximum value or from the maximum to the minimum
value)
Maximum reference input (MAXVAL): REAL
Minimum reference input (MINVAL): REAL
Reset value input (RESETVAL): REAL
Reset input (RESET): Boolean
Outputs
Output (OUTPUT) REAL
MOTPOT
62
TLA1 1 msec
(1)
ENABLE
UP
DOWN
RAMPTIME
MAXVAL
MINVAL
RESETVAL
RESET
OUTPUT
OUTPUT(62)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...