![ABB ACSM1 Series Manual Download Page 314](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326314.webp)
Fault tracing
314
Fault messages generated by the drive
Code
Fault
(fieldbus code)
Cause
What to do
0001
OVERCURRENT
(0x2310)
Output current has exceeded
internal fault limit.
Check motor load.
Check acceleration time. See parameter
group
on page
Check motor and motor cable (including
phasing and delta/star connection).
Check that the start-up data in parameter
group
corresponds to the motor rating
plate.
Check that there are no power factor
correction capacitors or surge absorbers in
motor cable.
Check encoder cable (including phasing).
0002
DC OVERVOLTAGE
(0x3210)
Excessive intermediate circuit
DC voltage.
Check that overvoltage controller is on,
parameter
.
Check mains for static or transient
overvoltage.
Check braking chopper and resistor (if used).
Check deceleration time.
Use coast-to-stop function (if applicable).
Retrofit frequency converter with braking
chopper and braking resistor.
0003
DEVICE OVERTEMP
(0x4210)
Measured drive temperature
has exceeded internal fault limit.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
0004
SHORT CIRCUIT
(0x2340)
Short-circuit in motor cable(s) or
motor.
Check motor and motor cable.
Check that there are no power factor
correction capacitors or surge absorbers in
motor cable.
Check the braking chopper cabling.
Extension: 1
Short-circuit in the upper
transistor of the U-phase.
Contact your local ABB representative.
Extension: 2
Short-circuit in the lower
transistor of the U-phase.
Contact your local ABB representative.
Extension: 4
Short-circuit in the upper
transistor of the V-phase.
Contact your local ABB representative.
Extension: 8
Short-circuit in the lower
transistor of the V-phase.
Contact your local ABB representative.
Extension: 16
Short-circuit in the upper
transistor of the W-phase.
Contact your local ABB representative.
Extension: 32
Short-circuit in the lower
transistor of the W-phase.
Contact your local ABB representative.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...