Standard function blocks
402
Operation
The input (I) value is stored to the output (OA1…OA32) selected by the address input
(A) if the load input (L) or the set input (S) is 1. When the load input is set to 1, the input
(I) value is stored to the output only once. When the set input is set to 1, the input (I)
value is stored to the output every time the block is executed. The set input overrides
the load input.
If the reset input (R) is 1, all connected outputs are 0.
If the address input is 0, negative or exceeds the number of the outputs, all outputs
are 0.
Example:
Inputs
The input data type is selected by the user.
Address input (A): DINT
Reset input (R): Boolean
Load input (L): Boolean
Set input (S): Boolean
Input (I): DINT, INT, REAL, REAL24, Boolean
Outputs
The number of the output channels (1…32) is selected by the user.
Output (OA1…OA32): DINT, INT, REAL, REAL24, Boolean
SWITCH
(10063)
Illustration
Execution time
0.68 µs (when two inputs are used) + 0.50 µs (for every additional input). When all
inputs are used, the execution time is 15.80 µs.
Operation
The output (OUT) is equal to the corresponding input (IN) if the activate input (ACT) is 1.
Otherwise the output is 0.
Inputs
The input data type and the number of inputs (1…32) are selected by the user.
Activate input (ACT): Boolean
Input (IN1…IN32): INT, DINT, REAL, REAL24, Boolean
Outputs
Output (OUT1…OUT32): INT, DINT, REAL, REAL24, Boolean
S
L
R
A
I
OA1
OA2
OA3
OA4
1
0
0
2
150
0
150
0
0
0
0
0
2
120
0
150
0
0
0
1
0
3
100
0
150
100
0
1
0
0
1
200
200
150
100
0
1
1
0
4
250
200
150
100
250
1
1
1
2
300
0
0
0
0
SWITCH
(BOOL)
83
TLA1 1 msec
(1)
ACT
IN1
IN2
OUT1
OUT1(83)
OUT2
OUT2(83)
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...