![ABB ACSM1 Series Manual Download Page 342](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326342.webp)
Standard function blocks
342
Outputs
Output (O): INT, DINT
REG
(10038)
Illustration
Execution time
2.27 µs (when two inputs are used) + 1.02 µs (for every additional input). When all
inputs are used, the execution time is 32.87 µs.
Operation
The input (I1…I32) value is stored to the corresponding output (O1…O32) if the load
input (L) is set to 1 or the set input (S) is 1. When the load input is set to 1, the input
value is stored to the output only once. When the set input is 1, the input value is stored
to the output every time the block is executed. The set input overrides the load input.
If the reset input (R) is 1, all connected outputs are 0.
Example:
Inputs
The input data type and number of inputs (1…32) are selected by the user.
Set input (S): Boolean
Load input (L): Boolean
Reset input (R): Boolean
Input (I1…I32): Boolean, INT, DINT, REAL, REAL24
Outputs
Output (O1…O32): Boolean, INT, DINT, REAL, REAL24
REG
(BOOL)
68
TLA1 1 msec
(1)
S
>L
R
I1
I2
O1
O1(68)
O2
O2(68)
S
R
L
I
O1
previous
O1
0
0
0
10
15
15
0
0
0->1
20
15
20
0
1
0
30
20
0
0
1
0->1
40
0
0
1
0
0
50
0
50
1
0
0->1
60
50
60
1
1
0
70
60
0
1
1
0->1
80
0
0
O1
previous
is the previous cycle output value.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...