For example, retaining the existing motor ID run results in the drive will make a new
motor ID run unnecessary.
Restore of individual parameters can fail for the following reasons:
• The restored value does not fall within the minimum and maximum limits of the
drive parameter
• The type of the restored parameter is different from that in the drive
• The restored parameter does not exist in the drive (often the case when restoring
the parameters of a new firmware version to a drive with an older version)
• The backup does not contain a value for the drive parameter (often the case
when restoring the parameters of an old firmware version to a drive with a newer
version).
In these cases, the parameter is not restored; the backup/restore tool will warn the
user and offer a possibility to set the parameter manually.
User parameter sets
The drive has four user parameter sets that can be saved to the permanent memory
and recalled using drive parameters. It is also possible to use digital inputs to switch
between different user parameter sets. See the descriptions of parameters
…
.
A user parameter set contains all values of parameter groups 10 to 99 (except the
fieldbus communication configuration settings).
As the motor settings are included in the user parameter sets, make sure the
settings correspond to the motor used in the application before recalling a user set.
In an application where different motors are used with one drive, the motor ID run
needs to be performed with each motor and saved to different user sets. The
appropriate set can then be recalled when the motor is switched.
Drive-to-drive link
The drive-to-drive link is a daisy-chained RS-485 transmission line that allows basic
master/follower communication with one master drive and multiple followers. For
more information, see
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...