Start-up
17
Motor data entering
Open the parameter and signal list by selecting the Parameter
Browser of the appropriate drive.
Select the language.
Parameters are set as follows:
Select the parameter group (in this case 99 START-UP DATA) by
double-clicking it. Select the appropriate parameter by double-clicking
it and set the new value.
Select the motor type: asynchronous or permanent magnet motor.
Select the motor control mode. DTC is suitable for most cases. For
information on scalar control, see parameter
.
Enter the motor data from the motor nameplate.
Asynchronous motor nameplate example:
Permanent magnet motor nameplate example:
Note:
Set the motor data
to exactly the same value
as on the motor
nameplate. For example,
if the motor nominal
speed is 1470 rpm on the
nameplate, setting the
value of parameter
to
1500 rpm results in
wrong operation of the
drive.
With DTC control (
) at least
parameters
must be set. Better control accuracy can be
achieved by setting also parameters
…
M2AA 200 MLA 4
1475
1475
1470
1470
1475
1770
32.5
56
34
59
54
59
0.83
0.83
0.83
0.83
0.83
0.83
3GAA 202 001 - ADA
180
IEC 34-1
6210/C3
6312/C3
Cat. no
35
30
30
30
30
30
50
50
50
50
50
60
690 Y
400 D
660 Y
380 D
415 D
440 D
V
Hz
kW
r/min
A
cos
IA/IN t E/s
Ins.cl. F
IP 55
No
IEC 200 M/L 55
3
motor
ABB Motors
380 V
mains
voltage
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...