Parameters and firmware blocks
106
6.02
STATUS WORD 2
(page
)
Status word 2.
Bit
Name
Val.
Information
0
START ACT
1
Drive start command is active.
0
Drive start command is inactive.
1
STOP ACT
1
Drive stop command is active.
0
Drive stop command is inactive.
2
READY RELAY
1
Ready to function: run enable signal on, no fault, emergency stop
signal off, no motor ID run inhibition. Connected by default to DIO1
by par.
. (Can be freely connected anywhere.)
0
Not ready to function
3
MODULATING
1
Modulating: IGBTs are controlled, ie, the drive is RUNNING.
0
No modulation: IGBTs are not controlled.
4
REF RUNNING
1
Normal operation is enabled. Running. Drive follows the given
reference.
0
Normal operation is disabled, Drive is not following the given
reference (eg, in magnetisation phase drive is modulating).
5
JOGGING
1
Jogging function 1 or 2 is active.
0
Jogging function is inactive.
6
OFF1
1
Emergency stop OFF1 is active.
0
Emergency stop OFF1 is inactive.
7
START INH
MASK
1
Maskable (by par.
) start inhibit is active.
0
No start inhibit (maskable)
8
START INH
NOMASK
1
Non-maskable start inhibit is active.
0
No start inhibit (non-maskable)
9
CHRG REL
CLOSED
1
Charging relay is closed.
0
Charging relay is open.
10
STO ACT
1
Safe Torque Off function is active. See parameter
0
Safe Torque Off function is inactive.
11
Reserved
12
RAMP IN 0
1
Ramp Function Generator input is forced to zero.
0
Normal operation
13
RAMP HOLD
1
Ramp Function Generator output is held.
0
Normal operation
14
RAMP OUT 0
1
Ramp Function Generator output is forced to zero.
0
Normal operation
15
DATA LOGGER
ON
1
The drive data logger is on and has not been triggered.
0
The drive data logger is off, or its post-trigger time has not yet
elapsed. See the DriveStudio user manual.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...