![ABB ACSM1 Series Manual Download Page 346](http://html.mh-extra.com/html/abb/acsm1-series/acsm1-series_manual_2326346.webp)
Standard function blocks
346
Operation
Configures the transmission between the dataset tables of drives.
The Msg Type input defines the message type as follows:
See also section
Examples of using standard function blocks in drive-to-drive
Value
Message type
0
Disabled
1
Master P2P:
The master sends the contents of a local dataset (specified by LocalDsNr
input) to the dataset table (dataset number specified by RemoteDsNr input)
of a follower (specified by Target Node/Grp input).
The follower replies by sending the next dataset (Remo 1) to the
master (Loc 1).
The node number of a drive is defined by parameter
Note:
Only supported in the master drive.
2
Read Remote:
The master reads a dataset (specified by RemoteDsNr input) from a follower
(specified by Target Node/Grp input) and stores it into local dataset table
(dataset number specified by LocalDsNr input).
The node number of a drive is defined by parameter
Note:
Only supported in the master drive.
3
Follower P2P:
The follower sends the contents of a local dataset (specified by LocalDsNr
input) to the dataset table (dataset number specified by RemoteDsNr input)
of another follower (specified by Target Node/Grp input).
The node number of a drive is defined by parameter
Note:
Only supported in a follower drive. A token from the master drive is
required for the follower to be able to send the message. See the block
.
4
Standard Multicast:
The drive sends the contents of a local dataset (specified by LocalDsNr
input) to the dataset table (dataset number specified by RemoteDsNr input)
of a group of followers (specified by Target Node/Grp input).
Which multicast group a drive belongs to is defined by the Std Mcast Group
input of the
block.
A token from the master drive is required for a follower to be able to send the
message. See the block
.
5
Broadcast:
The drive sends the contents of a local dataset (specified by LocalDsNr
input) to the dataset table (dataset number specified by RemoteDsNr input)
of all followers.
A token from the master drive is required for a follower to be able to send the
message. See the block
.
Note:
With this message type, the Target Node/Grp input must be
connected in DriveSPC even if not used.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...