Parameters and firmware blocks
240
65.22
PROF VEL REF SEL
(see above)
Selects the source for the speed reference in profile velocity mode. The profile velocity mode is
activated by parameter
, depending on the control location used.
(0)
ZERO
Zero reference.
(1)
AI1
Analogue input 1.
(2)
AI2
Analogue input 2.
(3)
FBA REF1
Fieldbus reference 1.
(4)
FBA REF2
Fieldbus reference 2.
(5)
D2D REF1
Drive-to-drive reference 1.
(6)
D2D REF2
Drive-to-drive reference 2.
(7)
POS VEL REF
Profile velocity reference 1 defined by parameter
65.23
PROF VEL REF1
(see above)
Defines profile velocity reference 1. Used when parameter
is set to
The unit depends on parameter
-32768…32768
Profile velocity reference 1.
65.24
POS START MODE
(see above)
Selects the positioning start function. Note that positioning cannot be started if the drive has not been
already started.
(0)
NORMAL
When the drive has already been started, rising edge of a signal from
the source defined by parameter
activates the positioning. The input signal has to stay TRUE
during the homing task.
(1)
PULSE
When the drive has already been started, rising edge of a pulse from
the source defined by parameter
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...