Parameters and firmware blocks
238
Bit 7
Effective only when bit 4 = 1 and bit 2 = 0.
1 = When positioning is started by the rising edge of
, the motor rotates one
revolution exactly according to bits 0 and 1. This feature is provided in the roll-over mode only.
0 = One revolution positioning is disabled.
65.10
POS END SPEED 1
(see above)
Defines the positioning speed when target is reached when position reference set 1 is used.
The unit depends on parameter
-32768…32768
Positioning speed when target is reached for position reference set 1.
65.11
POS START 2
(see above)
Selects the source for the positioning start command when position reference set 2 is used.
Bit pointer: Group, index and bit.
65.12
POS REF 2 SEL
(see above)
Selects the source for the positioning reference when position reference set 2 is used.
See
.
65.13
POS SPEED 2
(see above)
Defines the positioning speed when position reference set 2 is used.
The unit depends on parameter
0…32768
Positioning speed for position reference set 2.
65.14
PROF ACC 2
(see above)
Defines the positioning acceleration when position reference set 2 is used.
The unit depends on parameter
0…32768
Positioning acceleration for position reference set 2.
65.15
PROF DEC 2
(see above)
Defines the positioning deceleration when position reference set 2 is used.
The unit depends on parameter
-32768…0
Positioning deceleration for position reference set 2.
65.16
PROF FILT TIME 2
(see above)
Defines the position reference filter time when position reference set 2 is used.
0…1000 ms
Position reference filter time for position reference set 2.
65.17
POS STYLE 2
(see above)
Determines the behaviour of the position profile generator when position reference set 2 is used. See
parameter
0b0000000…0b1111111
Positioning style for position reference set 2.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...