Parameters and firmware blocks
224
62.01
HOMING METHOD
(see above)
Selects the homing method.
Note:
For cyclic corrections to work, this parameter must be set to
.
For more information, see
• section
•
on page
•
CiA Standard Proposal 402: CANopen Device Profile Drives and Motion Control
.
(0)
No Method
None.
(1)
CAN Method 1 …
(35)
CAN Method35
Homing method 1…35.
62.02
HOMING STARTFUNC
(see above)
Selects the homing start function.
(0)
Normal
Rising edge of a signal from the source defined by
START activates the homing. The input signal has to stay TRUE
during the homing task.
(1)
Pulse
Rising edge of a pulse from the source defined by
START activates the homing.
62.03
HOMING START
(see above)
Selects the source of the start command used in homing. 0 -> 1: Start. The start function is defined by
parameter
.
Bit pointer: Group, index and bit.
62.04
HOME SWITCH TRIG
(see above)
Selects the source for the home switch signal.
(0)
ENC1_DI1
Encoder 1 digital input DI1.
(1)
ENC1_DI2
Encoder 1 digital input DI2.
(2)
ENC2_DI1
Encoder 2 digital input DI1.
(3)
ENC2_DI2
Encoder 2 digital input DI2.
(4)
PROBE1 SW
Trigger probe 1 signal selected by parameter
. Used with homing methods 19…30.
62.05
NEG LIMIT SWITCH
(see above)
Selects the source for the negative limit switch signal (ie, external latch signal source for the minimum
position). Used to prevent movement beyond a certain minimum position (drive stopped along
emergency stop ramp), and with homing methods 1, 11…14, 17 and 27…30. Homing method is
selected by parameter
.
Bit pointer: Group, index and bit.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...