Parameters and firmware blocks
222
60.12
POS SPEED SCALE
(see above)
Defines an additional scaling for internal positioning speed, acceleration and deceleration values. Can
be used, eg, to improve calculation accuracy at low and high speeds.
Example: If parameter value is set to 0.1, internal speed value 1 rev/s is changed to value 10 rev/s.
0…32768
Additional scaling factor.
60.13
MAXIMUM POS
(see above)
Defines the maximum position value. If the actual position value exceeds the maximum position limit,
fault message POSERR MAX is generated.
The unit depends on parameter
selection.
0…32768
Maximum position value.
60.14
MINIMUM POS
(see above)
Defines the minimum position value. If the actual position value falls below the minimum position limit,
fault message POSERR MIN is generated.
The unit depends on parameter
selection.
-32768…0
Minimum position value.
60.15
POS THRESHOLD
(see above)
Defines the position threshold supervision limit. If actual position
exceeds the defined
limit,
bit 10 ABOVE THRES is activated.
The unit depends on parameter
selection.
-32768…32768
Position threshold supervision limit.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...