Parameters and firmware blocks
109
6.09
POS CTRL STATUS
(page
)
Position control status word.
Bit
Name
Val.
Information
0
IN POSITION
1
Position reference generator has reached the used position reference.
0
Position reference generator is active, ie, calculating the position refer-
ence.
1
IN POS WIN
1
Difference between position reference and actual position is within the
defined position window,
.
0
Difference between position reference and actual position is outside the
defined position window.
2
POS START
1
Positioning start command is active. Source for the start signal is
selected by parameter
.
0
Position start command is inactive.
3
POS ENA-
BLED
1
Position control is enabled by parameter
or by
fieldbus control word
bit 21.
0
Position control is not enabled.
4
MOVING
1
Positioning task is active. Drive speed is <> 0.
0
Positioning task is completed or drive is at standstill.
5
TRAVERSE
ACK
1
New positioning task or setpoint is accepted.
0
No operation
6
IP MODE
ACT
1
Position reference generator is active.
0
Position reference generator is inactive.
7
FOLLOW
ERR
1
The difference between the reference and the actual position is outside
the defined following error window.
0
The difference between the reference and the actual position is within
the defined following error window
.
8
ABOVE MAX
1
Actual position (
) exceeds the defined maximum
position,
.
0
Actual position does not exceed the maximum value.
9
BELOW MIN
1
) exceeds the defined minimum position,
0
Actual position does not exceed the minimum value.
10
ABOVE
THRES
1
Actual position (
) exceeds the position threshold
supervision limit. The limit is defined by parameter
.
0
Actual position does not exceed the position threshold supervision limit.
11
Reserved
12
PREF SPD
LIM
1
Position reference speed is limited to the value defined by parameter
0
Position reference speed is not limited.
13
PREF ACC
LIM
1
Position reference acceleration is limited to the value defined by
parameter
.
0
Position reference acceleration is not limited.
14
PREF DEC
LIM
1
Position reference deceleration is limited to the value defined by
parameter
.
0
Position reference deceleration is not limited.
15
Reserved
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...