Parameters and firmware blocks
243
66.03
PROF ACC WEAK SP
(see above)
Defines a positioning speed value (for the profile generator), above which acceleration/deceleration is
slowed down. Because the drive power depends on the torque and angular velocity, this parameter
defines the power limit used in the position reference calculation.
P = T ×
ω
and T = J × d
ω
/dt, where
T = torque
ω
= angular speed
J = Inertia
d
ω
/dt = angular acceleration
In other words, when the angular velocity exceeds the defined speed value, the power is limited by
reducing the angular acceleration(/deceleration).
The unit depends on parameter
0…32768
Acceleration/deceleration time breakpoint.
66.04
POS WIN
(see above)
Defines the absolute value for the positioning window supervision.
• When the difference between position reference and actual position is within the window defined by
this parameter, the positioning is completed. Then,
bit 19 are set to 1.
• When the value of position reference generator distance to target is within the window defined by
this parameter,
bit 0 is set.
Parameter value must be smaller than the value set by parameter
.
The unit depends on parameter
selection.
0…32768
Absolute value for positioning window supervision.
66.05
POS ENABLE
(see above)
Selects the source for enabling the position reference generator and the calculation of the position
reference. The state of the enable signal is reflected by
, bit 3.
1 = Enable / Continue position reference calculation.
0 = Disable. Position reference calculation is stopped. Generator output speed is decreased to zero
along the position deceleration ramp.
Bit pointer: Group, index and bit.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...