Parameters and firmware blocks
251
70.05
POS ACCEL LIM
(see above)
Limits the positioning acceleration rate. An active limitation is indicated by
,
bit 13.
The unit depends on parameter
0…32768
Positioning acceleration rate limit.
70.06
POS DECEL LIM
(see above)
Limits the positioning deceleration rate. An active limitation is indicated by
,
bit 14.
The unit depends on parameter
-32768…0
Positioning deceleration rate limit.
70.07
SYNC ERR LIM
(see above)
Defines the absolute value for the synchron error supervision window. The status is indicated by
, bit 0.
The unit depends on parameter
selection.
0…32768
Absolute value for synchron error supervision window.
70.08
SYNC VEL WINDOW
(see above)
Defines the absolute value for a synchronous velocity supervision window. If the difference between
synchronous speed and drive load speed is within the window, the limit bit 2 (
) is set in
.
The unit depends on parameter
0…32768
Absolute value for synchronous velocity supervision window.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...