Parameters and firmware blocks
246
67.03
INTERPOLAT MODE
(see above)
Selects whether the synchronisation reference selected by parameter
is
interpolated or not. This function can be used to smooth out short breaks in the reference.
(0)
NONE
Interpolation is not used. The synchronisation reference is reflected
directly by actual signal
.
(1)
INTERPOLATE
The synchronisation reference is interpolated as shown in the diagram
below.
The synchronisation reference is sampled at intervals defined by
parameter
. Signal
is updated to the sampled reference value after one cycle.
67.04
INTERPOLAT CYCLE
(see above)
Interpolation cycle for synchronisation reference. Used if the drive does not receive a changing
position reference from the synchronisation reference source. During the cycle, the drive calculates
an internal synchronisation position reference according to the previous cycle reference delta. After
the cycle, the drive updates the new value to signal
See also parameter
1…10000 ms
Interpolation cycle.
67.10
VIRT MAS SPD REF
(see above)
Defines the virtual master speed reference when parameter
is set to
-30000…30000 rpm
Virtual master speed reference.
Synchronisation
reference
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...