Parameters and firmware blocks
250
70
Firmware block:
POS REF LIM
(70)
This block
• selects the sources for the dynamic
limiter inputs
• selects the source for the position
reference enable command
• selects the positioning speed,
acceleration rate and deceleration
limits
• defines the synchron error
supervision window
• shows the limited position
reference and the synchronising
error caused by the dynamic
limitations or position correction
• defines the velocity window for
synchronous velocity supervision.
Block outputs located in other
parameter groups
(page
70.01
POS REF PROFILE
(see above)
Selects the source for the position reference for the dynamic limiter. Default value is P.4.13, ie,
firmware block (see page
).
Value pointer: Group and index.
70.02
POS REF SYNC
(see above)
Selects the source for the position reference for the dynamic limiter (added to
). Default value is P.4.16, ie,
, which is the output of the
firmware block (see page
Value pointer: Group and index.
70.03
POS REF ENA
(see above)
Selects the source for the position reference enable command. 1 = Enabled. 0 = Disabled, position
reference speed limit is set to zero and any on-going positioning task is interrupted.
Bit pointer: Group, index and bit
70.04
POS SPEED LIM
(see above)
Limits the positioning reference speed. An active limitation is indicated by
,
bit 12.
The unit depends on parameter
0…32768
Position reference speed limit.
POS REF LIM
10
TLF4 500 μsec
(1)
< 70.01 POS REF PROFILE
[ POS REF IPO ]
(9 / 4.13)
< 70.02 POS REF SYNC
[ SYNC REF GEARED ]
(10 / 4.16)
< 70.03 POS REF ENA
[ TRUE ]
70.04 POS SPEED LIM
[ 32768.000 u/s ]
70.05 POS ACCEL LIM
[ 32768.000 u/s^2 ]
70.06 POS DECEL LIM
[ -32768.000 u/s^2 ]
70.07 SYNC ERR LIM
[ 32768.000 rev ]
70.08 SYNC VEL WINDOW
[ 2.000 u/s ]
4.17 POS REF LIMITED
4.18 SYNC ERROR
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...