DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-16
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are interactive LCD button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!#*
and then enter the DB Admin password
“
########
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
•
Input
04-14-01-01
to program the
Owner
of DSS Console #1.
•
Press [
save
]. The current programming of the DSS Console #1
Owner
displays.
•
To change the designated DSS Console
Owner
press [
chg
] (change).
•
Enter the extension number to be assigned as the DSS Console
Owner
.
Note: Only valid (equipment installed) extension directory numbers can be assigned as DSS Console
Owners.
•
Press [
save
].
•
Press [
next
]. The current directory of the DSS Console is display (“NULL” if empty).
•
Press [
chg
] to enter the new DSS Console directory number (the extension number of the digital port to
which the DSS Console is connected).
•
Press [
save
].
•
Press [
next
]. The display prompts you for the next DSS Console # to program. Valid entries are 1-12.
•
Enter the number of the next DSS Console to program or press the
Hold
button to return to the previous
programming menu for other programming requirements. Or, press the
On/Off
button twice to exit
programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
. The program title page displays.
•
Press any key at the program title page to enter the Main Menu.
•
Select PC-DBA from the Main Menu. The PC-DBA menu is then shown.
•
Select Programming from the PC-DBA menu.
Program DSS Console Owner/Port:
•
Use
¢£¤¥
to highlight “System Resource” and then press
«
.
•
The cursor is now positioned on the database item - “Attendant.”
•
Use
¢£¤¥
to highlight the database item “DSS Allocation.” The cursor is positioned on the database
item “DSS Unit 1, DIR No.”
•
Press
«
to select this data item for change. The data item is ready for input.
•
Input the directory number of the digital port to which the DSS Console is connected.
•
Press
«
. The data is stored.
•
Use
¢£¤¥
to highlight the DSS Unit 1, DSS Owner database item.
•
Press
«
to select this data item for change. The data item is ready for input.
•
Enter the extension directory number of the extension with which this DSS will operate.
•
Press
«
. The data is stored.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...