changed if necessary. Regardless of the modem extension (directory number), this number is used to connect the
external PC-DBA calling modem to the internal DX-80 modem.
Auto Log Off is set to determine how long a PC-DBA to DX-80 connection will stay connected before automatically
being terminated.
Log On Again is set determine how long the DX-80 system will wait before accepting a valid password for PC-DBA
programming whenever the wrong password has been entered three times. That is, if an attempt to access the DX-80
database via PC-DBA is unsuccessful because the entered password is incorrect, and this failure occurs three
times… The system will reject any attempt for access even if the entered password is correct. The Log On Again time
can be set to lengthen or shorten the time interval that determines when the system will begin to accept valid
password connection attempts.
Related Features
Database Administration – Via PC-DBA
Related Programming
System Application – PC-DBA Connection – Auto Log Off
System Application – PC-DBA Connection –Log On Again
System Resource – Built-in Modem – DIR No.
System Resource – Built-in Modem – Baud Rate
Operation
Refer to Database Administration – Via PC-DBA, F9-Modem for operation instructions to connect to the DX-
80 system remotely.
Conditions
a) Database Administration can be entered into by one programming facility simultaneously. Therefore if
someone is programming the system via the Key Telephone and via on-site PC-DBA, remote access to
Database Administration will not be possible.
b) If there is no automated attendant or Voice Processor equipped at the site to be remotely accessed, the
modem connection must be manually administered on site. (The attendant/user must transfer the call to the
modem directory number {199 at default}).
Default Settings
System Application – PC-DBA Connection – Auto Log Off = “20” minutes.
(Range is 10/20…60.)
System Application – PC-DBA Connection – Log On Again = 30 minutes.
(Range is 0/10…60.)
System Resource – Built-in Modem – DIR No. is set to “199.”
(Range is any extension number.)
System Resource – Built-in Modem – Baud Rate is set to “2400.” (Range is 1200/2400.)
Programming Abstract
•
Set the Auto Log Off time to the length that a PC-DBA connection should be allowed to remain inactive
before it is automatically disconnected.
•
Set the Log On Again time to the appropriate time to secure the system from invasion attempts.
•
Set the built-in modem directory number for the directory number.
•
Set the built-in modem baud rate for the necessary operation rate.
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...