
DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-171
3. Hang up to end the connection.
Analog Ports (Single Line Telephones)
To intrude on a busy extension, dial
8
.
Conditions
a) Your extension must have Intrusion Active set to “Y” (yes) for this feature to operate.
b) An Intrusion Tone will be presented to all parties when Intrusion is invoked (extensions and CO Lines).
c) Intrusion Tone may be deactivated.
LEGAL NOTICE:
This feature may violate privacy laws if used in a manner that is inconsistent with requirements of these
laws. Manufacturer assumes no responsibility with regard to the use of this feature. It is provided for the
virtue of ethical use only. YOU are responsible for using this feature appropriately considering all
applicable laws.
d) The busy extension must have Intrusion Accept set to “Y” (yes) for this feature to operate.
Default Settings
Extension – Intrusion Active is set to “N.” (Range is Y/N.)
Extension – Intrusion Accept is set to “Y.” (Range is Y/N.)
Extension – Intrusion Tone is set to “Y.” (Range is Y/N.)
Programming Abstract
•
Program the feature Intrusion Active to YES for those extensions that should have the ability to intrude on
calls at other extensions.
•
Program the feature Intrusion Accept to NO for those extensions that should never be intruded.
•
Program the feature Intrusion Tone to NO if the Intrusion tone should not be heard at the intruded extension
when another extension has intrusion-joined the conversation in progress.
LEGAL NOTICE:
This feature may violate privacy laws if used in a manner that is inconsistent with requirements of these
laws. Manufacturer assumes no responsibility with regard to the use of this feature. It is provided for the
virtue of ethical use only. YOU are responsible for using this feature appropriately considering all
applicable laws.
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
•
Input 01-101~156-11 to program Intrusion Active (where “101~156” = the extension number to program).
•
Press [
save
]. This advances to the Extension – xxx – Intrusion Active database item.
•
Press [
chg
] until the appropriate setting displays.
•
Press the [
next
] to select the next data item to be changed. (Intrusion Accept, Intrusion Tone).
•
Press [
chg
] until the appropriate setting displays.
•
Continue making other programming changes or exit the programming mode.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...