DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-70
Enter into CO Line Group Directory Swapping (07-01-01~08-04):
•
Input
07-01-0g-04
(where “g” = the CO Line Group number, 1-8).
•
Press [
show
]. The current directory number assigned to this CO Line Group displays.
•
Press [
show
] to swap this directory number with another CO Line group directory number. (9, 800-809).
•
Input the directory number that is to be used to access this CO Line Group. (Note: The selected number
must be assigned to this system resource in Flexible Numbering Plan.)
•
Press [
save
]. The data is stored.
•
Press the
Volume button
(up or down) to return to the Database Item Select screen or press [
next
] to
enter another CO Line Group number for which the directory number is to be swapped.
•
Continue making other programming changes or exit the programming mode.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “CO Line Application.” Then press
«
.
•
Use
¢£¤¥
to highlight “CO Line Group Directory Number Swapping.” Then press
«
. The current
CO Line Group numbers and the assigned directory number are displayed.
•
Use
¢£¤¥
to highlight the appropriate CO Line Group under the column “DIR # Swapping.” Then
press
«
.
•
Input the CO Line Group Directory Number for this CO Line Group.
•
Press
«
. The database item is temporarily stored.
•
Use
¢£¤¥
to highlight the next CO Line Group Directory Number to be changed.
•
Repeat the programming process for all CO Line Groups necessary.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...