Specifications
Current draw:
Use this chart to calculate the Amphour requirements of the DX-80 system based upon its configuration.
This information is typically used to apply UPS battery requirements.
Component
Current Draw
(Amps)
@ 117 VAC
Quantity
Extended
Total Amps
KSU1 (7201)
0.18A
1
0.18A
KSU2 (7202)
0.17A
1 max.
COM4 (7210)
0.02A
2 max.
DPM8 (7220)
0.01A
4 max.
APM4 (7230)
0.08A
3 max.
MDM (7249)
0.01A
1 max.
AAM (7240)
0.01A
1 max.
PC-8 (7243)
0.015A
1 max.
FL-4 (7241)
0.02A
1 max.
FL3HR (7241E)
0.01A
1 max.
DET (7260-00)
0.016A
48 max.
DSS (7266-00)
0.016A
12 max.
Station wire:
per DET, DSS, and IST
0.02A every 100 ft. of
24AWG
?
Multiply the unit times the quantity installed in the subject application (site) and
add the right column for the total current draw (Amps) @ 117VAC for this
site……