When you have completed all changes, press the
°
(escape) key to exit this database-programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Hold Abandon
Each CO line has a programming option that directs the system to monitor distant party disconnect. This is a useful
network
feature in busy office environments where the inside party accidentally presses the Hold, ICM or DSS button
while expecting the outside line conversation to be concluded. Anytime the system detects a disconnect signal from
the Central Office, an existing Hold condition will be released, freeing that line for future inbound/outbound traffic.
Related Features
Hold - Common (System)
Hold – Exclusive
CO Line Loop Supervision
(Talk/Hold Abandon)
Transfer
Related Programming
CO Line - Call Abandon
Call Handling - Hold Abandon Time
Conditions
a) All types of Hold (e.g., System Hold, Exclusive Hold, and Conference Hold) are subject to the Hold Abandon
feature.
b) Certain Central Offices do not provide loop supervision, these line should be marked Call Abandon = “N.”
c) At default Call abandon is enabled for all CO lines.
d) If the outside (held party) disconnects, the system will automatically release the held CO line.
e) The CO line must have the loop supervision interrupt signal from the local carrier for Hold Abandon to
function.
Default Settings
Call Handling – Category 1 – Hold Abandon Time is set to “600.” (Range is: 50-1000 milliseconds.)
Programming Abstract
•
Program the required Hold Abandon Time.
•
Program CO Lines for Call Abandon (see CO Line Loop Supervision).
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...