Press [
back
] or [
next
] to input another extension number and repeat the above operations to view other
extension passwords.
•
Press
the Hold button
to return to the previous menu level or press
the Volume button (up or down)
to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “System Resource.” Then press
«
.
•
Use
¢£¤¥
to highlight “User Password.” Then press
«
.
Program User Password Length:
•
Use
¢£¤¥
to highlight User Password Length, then press
«
.
•
Input the User Name Password Length (4-8), then press
«
.
Program Extension Password(s):
•
Use
¢£¤¥
to highlight the extension password to be changed and press
enter
.
•
Input the new numeric password then press
«
.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Extension Pick Up Groups
The system provides eight (8) Extension Pick Up Groups per Tenant Group for partitioning the system into separate
departments for organized call answering within the department.
As an Extension of a Pick Up Group, you may retrieve calls ringing at another extension within the same pick up
group. Extension Pick Up Groups are assigned in the Database Programming.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...