DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-211
•
If you press “
Y
” (yes), you will then be prompted “File Exists, Override?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Use
¢£¤¥
to highlight “System Resource” and then press
«
.
To program the built-in Modem Directory Number and/or Modem Baud Rate:
•
Use
¢£¤¥
to highlight “System Resource” and then press
«
.
•
Use
¢£¤¥
to highlight “Modem & Serial Port” and then press
«
.
•
Use
¢£¤¥
to highlight the database item “Built-In Modem – Directory Number.”
•
Press
«
.
•
Input the appropriate directory number (as allocated in System Application – Numbering Plan – Extension
Directory Numbers).
•
Press
«
.
Or...
•
Use
¢£¤¥
to highlight Built-in Modem – Baud Rate.
•
Press
«
until the appropriate value displays.
•
When all changes are made press the
°
(escape) key to exit this database-programming screen. You will
see the prompt: “Exit This Feature”; press “
Y
” for yes.
•
You will then be prompted to “Save Current Setting?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “File Exists, Override?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a
“
SEND
”
function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Ringing Level / Muted Ringing
Ringing Level - Ringing volume can be adjusted at each digital speakerphone. There are four levels of ringing
available. Ringing Tone can be adjusted per the user’s required setting using the Distinctive Ringing – Extension
feature.
Muted Ringing - When an extension is busy on a call – incoming intercom and CO line calls will automatically ring at
the lowest ring volume setting regardless of the level set by the extension. When the extension is idle, incoming calls
ring at the loudness level set by the user.
Operation
While the extension is idle, press
the Volume button
(up or down) to set the ringing level.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...