DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-52
Program the appropriate extension(s) for Predefined Call Forward (Wrong #, Busy and No Answer):
•
Input
01-101~156-29
(for the extension number) to program the appropriate extension
Wrong #
Dest
ination.
Or…
•
Input
01-101~156-30
(for the extension number) to program the appropriate extension
Busy
Dest
ination.
Or…
•
Input
01-101~156-31
(for the extension number) to program the appropriate extension
No Ans
Dest
ination.
•
Press [
save
]. This advances to the selected extension Predefined Forward database item.
•
Press [
chg
] to change the value of this data item.
•
Input the appropriate destination (this may be an extension number or UCD/Hunt Group number).
•
Press [
save
].
•
Press
the Volume button
(up or down) to return to the DB Item Select screen.
Or…
•
Use [
back
] or [
next
] to go to the appropriate database item for change.
Program the Predefined Forward Time as required:
•
Press
Volume button
(up or down) to return to the DB Item Select screen.
•
Input 03-39 to program the system Predefined (No Answer) Call Forward Time.
•
Press [
save
]. This advances to the Predefined FWD Time database item.
•
Press [
chg
] until the appropriate value displays.
•
Continue making other database changes, or... exit programming mode when changes are complete.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu.
Program the appropriate extension for the Predetermined Call Forward modes required:
•
Use
¢£¤¥
to highlight “Extension.” Then press
«
.
•
Use
¢£¤¥
to highlight “Predetermined FWD.” Then press
«
.
•
Use
¢£¤¥
to highlight “Wrong # Dest.,” “Predef FWD Busy Dest.,” or “Predef FWD NoAns Dest.” for
the appropriate extension (extensions are listed along the left side of the screen under the column “DIR#).
•
Press
«
select this database item for change.
•
Input the destination directory number (extension or UCD/Hunt Group) then press
«
.
Note: Frequently the destination for a predefined forward – no answer condition will be to the VM
UCD/Hunt Group, that directory number is 433.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...