DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-167
Hour Mode Selection (12/24)
Standard 12-hour time or 24-hour time mode can be selected for common display at all Digital Speakerphones.
Related Features
Attendant Administration
Alarm Clock - Extension
System Time/Date
Alarm Clock System
SMDR
CO Line Ringing Modes
Related Programming
System Application – Hour Mode
System Application – System Time
Conditions
a) When programming time related features, 24-hour format is used for input.
b) SMDR output is in 24-hour format regardless of the settings of Hour Mode.
c) The correct system time is entered in database programming along with the Hour Mode Selection, from any
Digital Speakerphone extension using the database-programming password.
d) The “AM” and “PM” indications are not displayed.
Default Settings
System Application – Hour Mode is set at “12” seconds. (Range is: 12/24.)
System Application – System Time
Programming Abstract
•
Program the appropriate Hour Mode.
•
Reference System Time and Date for setting system time.
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
•
Input 08-03, then press [
save
]. This advances to Hour Mode programming.
•
Press [
chg
] until the appropriate hour format displays.
•
Press
the Hold button
to return to the previous menu level or press
the Volume button (up or down)
to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “System Application.” Then press
«
.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...